Gas Cleaning and Conditioning

Cleaning of raw synthesis gases: Particles, alkaline salts, HCl, H2S, COS, CS2, NH3, and HCN are removed to avoid catalyst poisoning during fuel synthesis. The pilot plant is equipped with an innovative hot-gas cleaning system for particle filtration, pollutant decomposition and adsorption at 500 °C.

 

Gas Cleaning and Conditioning: Institute for Technical Chemistry (ITC)

 

 

 

Gasreinigung

 

 

 

 

Fig. 1: Gas cleaning

 

 

 

 

© KIT 2022